. Installation instructions Vigilon Compact panel based Fire detection and alarm system.

Gent vigilon

To remove an S-Quad Distributed alarm device load To fi t an S-Quad Lumped alarm device load To fi t a dust cover Vigilon Loop Diagnostic tool To remove a dust cover Typical Vigilon Compact System Vigilon compact parts Vigilon Compact panel. Vigilon COMPACT fire system Preface Abbreviations This is the third issue of the Installation Alternating current instructions for the Vigilon Compact panel Direct current having 2Km loop card. It covers the End of line approval of 60hz mains frequency, battery charge current data and fi. Installation Notes As fi tted drawings The power-up of the control panel The installer should acquire site specifi c information from the interested parties, and commissioning of the system is for details on the location of products done by the Servicing organisation.

GENT 2015 Designed to EN54 Pt 2 & 4 Healthy. This is the second issue of the operating instructions for the Vigilon panel based fi re. This manual are not.

Gent Vigilon

For installation. Vigilon COMPACT fire system Earth continuity Local Manual Call Point All earth connection points should To comply with the requirements of be clean to provide a good electrical EN54-2: 1997 a conventional manual call conductivity path. To maintain the earth point must be installed near the Control continuity: all earth leads and fi.

Local Manual Call Point EN54 information Optional functions with requirements of European standard The Control panel complies with the requirements of EN54-2: 1997. In addition to the basic requirements of the standard the panel conforms to the following optional clauses: Clause Description. Vigilon COMPACT fire system System wiring If instructed, the installer may need to terminate as well as connect the cables to the appropriate terminal blocks.

Cable separation Where the outgoing and return cables of a loop circuit covers more than the equivalent of one zone they must not run together, for example, either close to the Control Panel or in a service duct. Requirements of cables Cables Mains Supply cable The mains supply cable must be a Requirements of cables standard fi re resisting type and should The British Standard meet PH30 classifi cation, such as BS 5839 Part 1: 2013 Code of standard or enhanced cable. Vigilon COMPACT fire system Enhanced loop cables Loop cables Approved cables for loop wiring There is a maximum limit (EMC Compliant) of 2Km loop cable usage Draka Firetuf FT120 Enhanced -  allowed per loop circuit. FTPLUS2EH1.5RD This maximum limit is the. Network cables Prysmian (formally Pirelli) FP Plus.  1.2Km maximum Panel to Panel or Panel to Network node cable distance The cables marked. utilise 3 Cores each having 1.5mm cross  laminated aluminium tape with a section area tinned drain wire for electrostatic screening.

Vigilon COMPACT fire system Belden TR No. 89729 Prysmian (formally Pirelli)   (Tefl on jacketed) FP200 Flex. 1.2Km maximum Panel to Panel or 800m maximum Panel to Panel or Panel to Network node cable distance Panel to Network node cable distance 2 twisted pairs 3 Cores, each having 1.5mm. Condition of use The Loop Card (COMPACT-LPC-EN) must never be fi tted as a replacement card in a Vigilon Compact panel where 3400 devices are installed on its loop circuits. Up to 2Km loop length is possible with S4 and S3 Mark 2 devices installed on a . Vigilon Loop Diagnostic tool The Vigilon Loop Diagnostic Tool can be used to diagnose loop circuits driven by Post March 2014 Loop Cards (COMPACT-LPC-EN) fi tted in the panel, this is normally done. Typical Vigilon Compact System Typical Vigilon Compact System The loop allows wiring of addressable devices like fi re sensors, alarm sounders, call points, interface units, mimic and repeat panels, a combined maximum of up to 200 devices are allowed per loop circuit.

Gent Vigilon En54 Manual

2 loop circuits each up  via batteries for 24 hours plus 0.5 hour to 2Km in length that alarm load can have Vigilon analogue addressable LCD with back light to display event devices, like fi re sensors, manual call  information points, interface units and repeat panels.